References
Disclaimer
Please respect&protect the privacy of others.
The purpose of this software is not to spy on others, but to detect network anomalies and malicious traffic.
Abstract
nDPId is a set of daemons and tools to capture, process and classify network traffic. It's minimal dependencies (besides a half-way modern c library and POSIX threads) are libnDPI (>=4.8.0 or current github dev branch) and libpcap.
The daemon nDPId
is capable of multithreading for packet processing, but w/o mutexes for performance reasons.
Instead synchronization is achieved by a packet distribution mechanism.
To balance all workload to all threads (more or less) equally a unique identifier represented as hash value is calculated using a 3-tuple consisting of IPv4/IPv6 src/dst address, IP header value of the layer4 protocol and (for TCP/UDP) src/dst port. Other protocols e.g. ICMP/ICMPv6 are lacking relevance for DPI, thus nDPId does not distinguish between different ICMP/ICMPv6 flows coming from the same host. Saves memory and performance, but might change in the future.
nDPId
uses libnDPI's JSON serialization interface to generate a JSON strings for each event it receive from the library and which it then sends out to a UNIX-socket (default: /tmp/ndpid-collector.sock ). From such a socket, nDPIsrvd
(or other custom applications) can retrieve incoming JSON-messages and further proceed working/distributing messages to higher-level applications.
Unfortunately nDPIsrvd
does currently not support any encryption/authentication for TCP connections (TODO!).
Architecture
This project uses some kind of microservice architecture.
connect to UNIX socket [1] connect to UNIX/TCP socket [2]
_______________________ | | __________________________
| "producer" |___| |___| "consumer" |
|---------------------| _____________________________ |------------------------|
| | | nDPIsrvd | | |
| nDPId --- Thread 1 >| ---> |> | <| ---> |< example/c-json-stdout |
| (eth0) `- Thread 2 >| ---> |> collector | distributor <| ---> |________________________|
| `- Thread N >| ---> |> >>> forward >>> <| ---> | |
|_____________________| ^ |____________|______________| ^ |< example/py-flow-info |
| | | | |________________________|
| nDPId --- Thread 1 >| `- send serialized data [1] | | |
| (eth1) `- Thread 2 >| | |< example/... |
| `- Thread N >| receive serialized data [2] -' |________________________|
|_____________________|
where:
nDPId
capture traffic, extract traffic data (with libnDPI) and send a JSON-serialized output stream to an already existing UNIX-socket;-
nDPIsrvd
:- create and manage an "incoming" UNIX-socket (ref [1] above), to fetch data from a local
nDPId
; - apply a buffering logic to received data;
- create and manage an "outgoing" UNIX or TCP socket (ref [2] above) to relay matched events to connected clients
- create and manage an "incoming" UNIX-socket (ref [1] above), to fetch data from a local
-
consumers
are common/custom applications being able to receive selected flows/events, via both UNIX-socket or TCP-socket.
JSON stream format
JSON messages streamed by both nDPId
and nDPIsrvd
are presented with:
- a 5-digit-number describing (as decimal number) of the entire JSON string including the newline
\n
at the end; - the JSON messages
[5-digit-number][JSON string]
as with the following example:
01223{"flow_event_id":7,"flow_event_name":"detection-update","thread_id":12,"packet_id":307,"source":"wlan0",[...]}
00458{"packet_event_id":2,"packet_event_name":"packet-flow","thread_id":11,"packet_id":324,"source":"wlan0",[...]]}
00572{"flow_event_id":1,"flow_event_name":"new","thread_id":11,"packet_id":324,"source":"wlan0",[...]}
The full stream of nDPId
generated JSON-events can be retrieved directly from nDPId
, without relying on nDPIsrvd
, by providing a properly managed UNIX-socket.
Technical details about JSON-messages format can be obtained from related .schema
file included in the schema
directory
Events
nDPId
generates JSON strings whereas each string is assigned to a certain event.
Those events specify the contents (key-value-pairs) of the JSON string.
They are divided into four categories, each with a number of subevents.
Error Events
They are 17 distinct events, indicating that layer2 or layer3 packet processing failed or not enough flow memory available:
- Unknown datalink layer packet
- Unknown L3 protocol
- Unsupported datalink layer
- Packet too short
- Unknown packet type
- Packet header invalid
- IP4 packet too short
- Packet smaller than IP4 header:
- nDPI IPv4/L4 payload detection failed
- IP6 packet too short
- Packet smaller than IP6 header
- nDPI IPv6/L4 payload detection failed
- TCP packet smaller than expected
- UDP packet smaller than expected
- Captured packet size is smaller than expected packet size
- Max flows to track reached
- Flow memory allocation failed
Detailed JSON-schema is available here
Daemon Events
There are 4 distinct events indicating startup/shutdown or status events as well as a reconnect event if there was a previous connection failure (collector):
- init:
nDPId
startup - reconnect: (UNIX) socket connection lost previously and was established again
- shutdown:
nDPId
terminates gracefully - status: statistics about the daemon itself e.g. memory consumption, zLib compressions (if enabled)
Detailed JSON-schema is available here
Packet Events
There are 2 events containing base64 encoded packet payload either belonging to a flow or not:
- packet: does not belong to any flow
- packet-flow: does belong to a flow e.g. TCP/UDP or ICMP
Detailed JSON-schema is available here
Flow Events
There are 9 distinct events related to a flow:
- new: a new TCP/UDP/ICMP flow seen which will be tracked
- end: a TCP connections terminates
- idle: a flow timed out, because there was no packet on the wire for a certain amount of time
- update: inform nDPIsrvd or other apps about a long-lasting flow, whose detection was finished a long time ago but is still active
- analyse: provide some information about extracted features of a flow (Experimental; disabled per default, enable with
-A
) - guessed:
libnDPI
was not able to reliable detect a layer7 protocol and falls back to IP/Port based detection - detected:
libnDPI
sucessfully detected a layer7 protocol - detection-update:
libnDPI
dissected more layer7 protocol data (after detection already done) - not-detected: neither detected nor guessed
Detailed JSON-schema is available here. Also, a graphical representation of Flow Events timeline is available here.
Flow States
A flow can have three different states while it is been tracked by nDPId
.
- skipped: the flow will be tracked, but no detection will happen to safe memory, see command line argument
-I
and-E
- finished: detection finished and the memory used for the detection is free'd
- info: detection is in progress and all flow memory required for
libnDPI
is allocated (this state consumes most memory)
Build (CMake)
nDPId
build system is based on CMake
git clone https://github.com/utoni/nDPId.git
[...]
cd ndpid
mkdir build
cd build
cmake ..
[...]
make
see below for a full/test live-session
Based on your building environment and/or desiderata, you could need:
mkdir build
cd build
ccmake ..
or to build with a staticially linked libnDPI:
mkdir build
cd build
cmake .. -DSTATIC_LIBNDPI_INSTALLDIR=[path/to/your/libnDPI/installdir]
If you're using the latter one, make sure that you've configured libnDPI with ./configure --prefix=[path/to/your/libnDPI/installdir]
and do not forget to set the all necessary CMake variables to link against shared libraries used by your nDPI build.
e.g.:
mkdir build
cd build
cmake .. -DSTATIC_LIBNDPI_INSTALLDIR=[path/to/your/libnDPI/installdir] -DNDPI_WITH_GCRYPT=ON -DNDPI_WITH_PCRE=OFF -DNDPI_WITH_MAXMINDDB=OFF
Or let a shell script do the work for you:
mkdir build
cd build
cmake .. -DBUILD_NDPI=ON
The CMake cache variable -DBUILD_NDPI=ON
builds a version of libnDPI
residing as git submodule in this repository.
run
As mentioned above, in order to run nDPId
a UNIX-socket need to be provided in order to stream our related JSON-data.
Such a UNIX-socket can be provided by both the included nDPIsrvd
daemon, or, if you simply need a quick check, with the ncat utility, with a simple ncat -U /tmp/listen.sock -l -k
. Remember that OpenBSD netcat
is not able to handle multiple connections reliably.
Once the socket is ready, you can run nDPId
capturing and analyzing your own traffic, with something similar to:
Of course, both ncat
and nDPId
need to point to the same UNIX-socket (nDPId
provides the -c
option, exactly for this. As a default, nDPId
refer to /tmp/ndpid-collector.sock
, and the same default-path is also used by nDPIsrvd
as for the incoming socket).
You also need to provide nDPId
some real-traffic. You can capture your own traffic, with something similar to:
socat -u UNIX-Listen:/tmp/listen.sock,fork - # does the same as `ncat`
sudo chown nobody:nobody /tmp/listen.sock # default `nDPId` user/group, see `-u` and `-g`
sudo ./nDPId -c /tmp/listen.sock -l
nDPId
supports also UDP collector endpoints:
nc -d -u 127.0.0.1 7000 -l -k
sudo ./nDPId -c 127.0.0.1:7000 -l
or you can generate a nDPId-compatible JSON dump with:
./nDPId-test [path-to-a-PCAP-file]
You can also automatically fire both nDPId
and nDPIsrvd
automatically, with:
Daemons:
make -C [path-to-a-build-dir] daemon
Or you can proceed with a manual approach with:
./nDPIsrvd -d
sudo ./nDPId -d
or for a usage printout:
./nDPIsrvd -h
./nDPId -h
And why not a flow-info example?
./examples/py-flow-info/flow-info.py
or
./nDPIsrvd-json-dump
or anything below ./examples
.
nDPId tuning
It is possible to change nDPId
internals w/o recompiling by using -o subopt=value
.
But be careful: changing the default values may render nDPId
useless and is not well tested.
Suboptions for -o
:
Format: subopt
(unit, comment): description
max-flows-per-thread
(N, caution advised): affects max. memory usagemax-idle-flows-per-thread
(N, safe): max. allowed idle flows which memory get's free'd afterflow-scan-interval
max-reader-threads
(N, safe): amount of packet processing threads, every thread can have a max. ofmax-flows-per-thread
flowsdaemon-status-interval
(ms, safe): specifies how often daemon eventstatus
will be generatedcompression-scan-interval
(ms, untested): specifies how oftennDPId
should scan for inactive flows ready for compressioncompression-flow-inactivity
(ms, untested): the earliest period of time that must elapse beforenDPId
may consider compressing a flow that did neither send nor receive any dataflow-scan-interval
(ms, safe): min. amount of time after whichnDPId
will scan for idle or long-lasting flowsgeneric-max-idle-time
(ms, untested): time after which a non TCP/UDP/ICMP flow will time outicmp-max-idle-time
(ms, untested): time after which an ICMP flow will time outudp-max-idle-time
(ms, caution advised): time after which an UDP flow will time outtcp-max-idle-time
(ms, caution advised): time after which a TCP flow will time outtcp-max-post-end-flow-time
(ms, caution advised): a TCP flow that received a FIN or RST will wait that amount of time before flow tracking will be stopped and the flow memory free'dmax-packets-per-flow-to-send
(N, safe): max.packet-flow
events that will be generated for the first N packets of each flowmax-packets-per-flow-to-process
(N, caution advised): max. packets that will be processed bylibnDPI
max-packets-per-flow-to-analyze
(N, safe): max. packets to analyze before sending ananalyse
event, requires-A
test
The recommended way to run integration / diff tests:
mkdir build
cd build
cmake .. -DBUILD_NDPI=ON
make nDPId-test test
Alternatively you can run some integration tests manually:
./test/run_tests.sh [/path/to/libnDPI/root/directory] [/path/to/nDPId-test]
e.g.:
./test/run_tests.sh [${HOME}/git/nDPI] [${HOME}/git/nDPId/build/nDPId-test]
Remember that all test results are tied to a specific libnDPI commit hash
as part of the git submodule
. Using test/run_tests.sh
for other commit hashes
will most likely result in PCAP diff's.
Why not use examples/py-flow-dashboard/flow-dash.py
to visualize nDPId's output.
Contributors