aboutsummaryrefslogtreecommitdiff
path: root/tests/result/iec60780-5-104.pcap.out
diff options
context:
space:
mode:
authorIvan Nardi <12729895+IvanNardi@users.noreply.github.com>2022-01-11 15:23:39 +0100
committerGitHub <noreply@github.com>2022-01-11 15:23:39 +0100
commit3a087e951d96f509c75344ad6791591e10e4f1cd (patch)
treee1c83179768f1445610bf060917700f17fce908f /tests/result/iec60780-5-104.pcap.out
parenta2916d2e4c19aff56979b1dafa7edd0c7d3c17fe (diff)
Add a "confidence" field about the reliability of the classification. (#1395)
As a general rule, the higher the confidence value, the higher the "reliability/precision" of the classification. In other words, this new field provides an hint about "how" the flow classification has been obtained. For example, the application may want to ignore classification "by-port" (they are not real DPI classifications, after all) or give a second glance at flows classified via LRU caches (because of false positives). Setting only one value for the confidence field is a bit tricky: more work is probably needed in the next future to tweak/fix/improve the logic.
Diffstat (limited to 'tests/result/iec60780-5-104.pcap.out')
-rw-r--r--tests/result/iec60780-5-104.pcap.out13
1 files changed, 7 insertions, 6 deletions
diff --git a/tests/result/iec60780-5-104.pcap.out b/tests/result/iec60780-5-104.pcap.out
index 7fd3c51b5..ad4b72c32 100644
--- a/tests/result/iec60780-5-104.pcap.out
+++ b/tests/result/iec60780-5-104.pcap.out
@@ -1,12 +1,13 @@
Guessed flow protos: 0
DPI Packets (TCP): 24 (4.00 pkts/flow)
+Confidence DPI : 6 (flows)
IEC60870 147 9033 6
- 1 TCP 172.27.248.109:1578 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][cat: IoT-Scada/31][28 pkts/1758 bytes <-> 19 pkts/1297 bytes][Goodput ratio: 9/20][235.18 sec][bytes ratio: 0.151 (Mixed)][IAT c2s/s2c min/avg/max/stddev: 1/4 9106/11905 32485/32516 10297/10287][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 63/68 76/118 5/15][Plen Bins: 96,0,4,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
- 2 TCP 172.27.248.109:1568 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][cat: IoT-Scada/31][17 pkts/1040 bytes <-> 12 pkts/674 bytes][Goodput ratio: 7/3][160.96 sec][bytes ratio: 0.214 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 9874/10029 38294/26906 11815/8997][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 61/56 68/62 2/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
- 3 TCP 172.27.248.109:1572 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][cat: IoT-Scada/31][15 pkts/940 bytes <-> 10 pkts/572 bytes][Goodput ratio: 9/4][191.16 sec][bytes ratio: 0.243 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 12850/21996 59783/60001 22023/25276][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 63/57 76/62 5/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
- 4 TCP 172.27.248.109:1571 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][cat: IoT-Scada/31][10 pkts/609 bytes <-> 7 pkts/398 bytes][Goodput ratio: 5/3][102.90 sec][bytes ratio: 0.210 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 8708/15094 59736/60003 19503/25928][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 61/57 67/62 2/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
- 5 TCP 172.27.248.109:1570 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][cat: IoT-Scada/31][10 pkts/624 bytes <-> 6 pkts/344 bytes][Goodput ratio: 7/3][92.07 sec][bytes ratio: 0.289 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 11477/15000 42399/42717 16042/17488][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 62/57 72/62 4/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
- 6 TCP 172.27.248.109:1577 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][cat: IoT-Scada/31][8 pkts/493 bytes <-> 5 pkts/284 bytes][Goodput ratio: 6/2][36.61 sec][bytes ratio: 0.269 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/4 6100/11100 21872/22196 8836/11096][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 62/57 71/62 4/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
+ 1 TCP 172.27.248.109:1578 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][Confidence: DPI][cat: IoT-Scada/31][28 pkts/1758 bytes <-> 19 pkts/1297 bytes][Goodput ratio: 9/20][235.18 sec][bytes ratio: 0.151 (Mixed)][IAT c2s/s2c min/avg/max/stddev: 1/4 9106/11905 32485/32516 10297/10287][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 63/68 76/118 5/15][Plen Bins: 96,0,4,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
+ 2 TCP 172.27.248.109:1568 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][Confidence: DPI][cat: IoT-Scada/31][17 pkts/1040 bytes <-> 12 pkts/674 bytes][Goodput ratio: 7/3][160.96 sec][bytes ratio: 0.214 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 9874/10029 38294/26906 11815/8997][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 61/56 68/62 2/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
+ 3 TCP 172.27.248.109:1572 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][Confidence: DPI][cat: IoT-Scada/31][15 pkts/940 bytes <-> 10 pkts/572 bytes][Goodput ratio: 9/4][191.16 sec][bytes ratio: 0.243 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 12850/21996 59783/60001 22023/25276][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 63/57 76/62 5/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
+ 4 TCP 172.27.248.109:1571 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][Confidence: DPI][cat: IoT-Scada/31][10 pkts/609 bytes <-> 7 pkts/398 bytes][Goodput ratio: 5/3][102.90 sec][bytes ratio: 0.210 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 8708/15094 59736/60003 19503/25928][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 61/57 67/62 2/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
+ 5 TCP 172.27.248.109:1570 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][Confidence: DPI][cat: IoT-Scada/31][10 pkts/624 bytes <-> 6 pkts/344 bytes][Goodput ratio: 7/3][92.07 sec][bytes ratio: 0.289 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/0 11477/15000 42399/42717 16042/17488][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 62/57 72/62 4/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]
+ 6 TCP 172.27.248.109:1577 <-> 172.27.248.79:2404 [proto: 245/IEC60870][ClearText][Confidence: DPI][cat: IoT-Scada/31][8 pkts/493 bytes <-> 5 pkts/284 bytes][Goodput ratio: 6/2][36.61 sec][bytes ratio: 0.269 (Upload)][IAT c2s/s2c min/avg/max/stddev: 0/4 6100/11100 21872/22196 8836/11096][Pkt Len c2s/s2c min/avg/max/stddev: 60/54 62/57 71/62 4/3][Plen Bins: 100,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]